• Gossen Metrawatt
  • Gossen
  • Camille Bauer

Technical Features

METRATESTER 5+3P SECULIFE ST SECUTEST ST BASE SECULIFE ST HV SECUTEST ST PRO SECUTEST ST PRO BT COMFORT SECUTEST SIII+ H SECUTEST 21F SECUTEST SIII+
Item number M700K M693E M707A M693C M707B M707C M7010-V013 M601A M7010
Product details page Details Details Details Details Details Details Details Details Details
Supply voltage 115 - 230 90 - 250 115 - 230 90 - 250 90 - 250 115 - 230 1 - 253 115 - 230
Indication Digital Graphic Graphic Graphic Graphic Graphic Graphic Digital Graphic
Automatic test sequence x x x x x x x
Limit value indication x x x x x x x x x
Measured value memory x x x x x x x
Deadlines management No Yes Optional Yes Optional Yes No No No
Active testing x x x x x x x x
Passive testing x x x x x x x
Protective ground resistance measuring range 0.01Ohm - 19.99Ohm 0.001Ohm - 2.1Ohm 0.001Ohm - 30Ohm 0.001Ohm - 2.1Ohm 0Ohm - 30Ohm 0Ohm - 30Ohm 0Ohm - 30Ohm 0.01Ohm - 20Ohm 0.001Ohm - 2.1Ohm
Isolation resistance measuring range 0.05MOhm - 19,99MOhm 0.001MOhm - 310MOhm 1MOhm - 300MOhm 0.001MOhm - 310MOhm 0.01MOhm - 300MOhm 0.01MOhm - 300MOhm 0.05MOhm - 300MOhm 0.01MOhm - 20MOhm 0.005MOhm - 300MOhm
Protective conductor current x x x x x x x
Contact current x x x x x x x x x
Differential current method x x x x x x x x x
Direct method x x x x x x x x
Alternative method x x x x x x x x
Consumption current measurement x x x x x x x x x
Power measuring x x x x x x x x
Voltage measurement x x x x x x x x
Connection for external measuring adapter x x x x x x x x x
Testing of enlarging conduits x x x x x x x x
Testing with 2 probes No Optional No Optional Yes Yes Yes No Yes
Interface x x x x x
Printer connection x x x
Printer integrated
Suitable for use by an instructed person x x x x x x x
Connection detection x x x x x x x x
Description of RFID x x x
DAkkS calibration certificate x x x x x x x
Printing barcodes x x x x x
Import of data No No No Yes Yes No No No
Integrated rubber protection x x x
Measurement of time to trip of (P)RCDs x x
Save measurement series x x x
Test current 10A x x x x x x
remote compatible No No Optional No Yes Yes Yes No Yes
Safety class detection x x x x x x x x
Management of location data No No Optional No Optional Yes No No No
Programmable test sequences No No Optional No Yes Yes No No No
Frequency of supply voltage 50 - 60 50 - 400 50 - 60 50 - 400 50 - 400 50 - 60 45 - 100 50 - 60
Relocation management for site data (moving test objects) x x x
Test sequences per IEC/EN 62353 (medical devices) x x x x x x
Documentation software x x x x
Type of interface RS-232 USB-B RS-232 USB-B
High-voltage test 500V - 4000V 500V - 4000V
Test sequences per VDE 0544-4 (welding equipment) x x x
HTML report x x x
Test sequences for testing PRCDs x x x
Extension for testing and managing medical devices x x x x x
Printer Connection USB-A Other USB-A USB-A
Test sequences per IEC 60601 (medical devices) x
CC115226 Yes Optional Optional
CC115227 Yes Yes Optional
Data transmission to PC via BT/USB x