• Gossen Metrawatt
  • Gossen
  • Camille Bauer

Technical Features

SYSKON P3000 SYSKON P4500 SYSKON P800 SYSKON P1500 SYSKON P500
Item number K363A K364A K347A K353A K346A
Product details page Details Details Details Details Details
Chapter01 Computer interface Computer interface Computer interface Computer interface
IEC-625/IEEE 488 interface x x x x x
RS232 interface x x x x x
Transmission mode Asynchronous Asynchronous Asynchronous Asynchronous Asynchronous
Transmission speed RS232 1200 ... 115,200 baud, adjustable 1200 ... 115,200 baud, adjustable 1200 ... 115,200 baud, adjustable 1200 ... 115,200 baud, adjustable 1200 ... 115,200 baud, adjustable
USB interface x 4-pin, type B x 4-pin, type B x 4-pin, type B x 4-pin, type B x 4-pin, type B
USB compatible USB 1.1 compatible with 2.0 USB 1.1 compatible with 2.0 USB 1.1 compatible with 2.0 USB 1.1 compatible with 2.0 USB 1.1 compatible with 2.0
Terminal assignment D -
D +
GND
VCC
D -
D +
GND
VCC
VCC
D -
D +
GND
D -
D +
GND
VCC
VCC
D -
D +
GND
Transmission speed USB 9600 ... 115,200 baud, adjustable 9600 ... 115,200 baud, adjustable 9600 ... 115,200 baud, adjustable 9600 ... 115,200 baud, adjustable 9600 ... 115,200 baud, adjustable
Chapter02 Power supply Power supply Power supply Power supply Power supply
Line voltage 115/230 V ~ +10/-15%, 47 ... 63 Hz 115/230 V ~ +10/-15%, 47 ... 63 Hz 115/230 V ~ +10/-15%, 47 ... 63 Hz 115/230 V ~ +10/-15%, 47 ... 63 Hz 115/230 V ~ +10/-15%, 47 ... 63 Hz
Max. inrush current 50 As 50 As 50 As 50 As 50 As
Mains fuse (6.3x32mm,UL) 3 x M 15A / 250V 3 x M 15A / 250V 1 x M 15A / 250V 1 x M 15A / 250V 1 x M 15A / 250V
Chapter03 Electrical safety Electrical safety Electrical safety Electrical safety Electrical safety
Protection class I I I I I
Measurement category I for output and interfaces
II for mains input
I for output and interfaces
II for mains input
I for output and interfaces
II for mains input
I for output and interfaces
II for mains input
I for output and interfaces
II for mains input
Pollution degree 2 2 2 2 2
Earth leakage current < 2.5 mA TRMS < 2.5 mA TRMS < 2.5 mA TRMS < 2.5 mA TRMS < 2.5 mA TRMS
Electrical isolation Test voltage Test voltage Test voltage Test voltage Test voltage
Output - mains 2.2kV 2.2kV 2.2kV 2.2kV 2.2kV
Output - bus/mains 1.4kV 1.4kV 1.4kV 1.4kV 1.4kV
Mains - bus/earth 2.2kV 2.2kV 2.2kV 2.2kV 2.2kV
Bus - earth No electrical isolation No electrical isolation No electrical isolation No electrical isolation No electrical isolation
Chapter04 Ambient conditions Ambient conditions Ambient conditions Ambient conditions Ambient conditions
Temperature range Operation: 0 to 40 °C
Storage: -25 to 75 °C
Operation: 0 to 40 °C
Storage: -25 to 75 °C
Storage: -25 to 75 °C
Operation: 0 to 40 °C
Operation: 0 to 40 °C
Storage: -25 to 75 °C
Operation: 0 to 40 °C
Storage: -25 to 75 °C
Humidity Operation: ≤ 75% relative humidity
Storage: ≤ 65% relative humidity
Operation: ≤ 75% relative humidity
Storage: ≤ 65% relative humidity
Storage: ≤ 65% relative humidity
Operation: ≤ 75% relative humidity
Operation: ≤ 75% relative humidity
Storage: ≤ 65% relative humidity
Operation: ≤ 75% relative humidity
Storage: ≤ 65% relative humidity
Refrigeration Via integrated fan (temperature-controlled)
Air outlet: rear panel
Air intake: side panel
Via integrated fan (temperature-controlled)
Air outlet: rear panel
Air intake: side panel
Via integrated fan (temperature-controlled)
Air outlet: rear panel
Air intake: side panel
Via integrated fan (temperature-controlled)
Air outlet: rear panel
Air intake: side panel
Via integrated fan (temperature-controlled)
Air intake: side panel
Air outlet: rear panel
Operating noise Front: 17/28 dBA
Left: 17/28 dBA
Right: 20/31 dBA
Rear: 22/32 dBA
Front: 17/28 dBA
Left: 17/28 dBA
Right: 20/31 dBA
Rear: 22/32 dBA
Front: 17/28 dBA
Left: 17/28 dBA
Right: 20/31 dBA
Rear: 22/32 dBA
Front: 17/28 dBA
Rear: 22/32 dBA
Left: 17/28 dBA
Right: 20/31 dBA
Front: 17/28 dBA
Left: 17/28 dBA
Right: 20/31 dBA
Rear: 22/32 dBA
Chapter05 Electrical safety and mechanical data Electrical safety and mechanical data Electrical safety and mechanical data Electrical safety and mechanical data Electrical safety and mechanical data
Product standard EN 61326 - 1: October 2006 EN 61326 - 1: October 2006 EN 61326 - 1: October 2006 EN 61326 - 1: October 2006 EN 61326 - 1: October 2006
Interference emission EN 55022: Class A * EN 55022: Class A * EN 55022: Class B EN 55022: Class B EN 55022: Class B
Interference immunity EN 61000-4-2: Feature B
EN 61000-4-3: Feature A
EN 61000-4-4: Feature B
EN 61000-4-5: Feature B
EN 61000-4-6: Feature A
EN 61000-4-8: Feature A
EN 61000-4-11: Feature B
EN 61000-4-2: Feature B
EN 61000-4-3: Feature A
EN 61000-4-4: Feature B
EN 61000-4-5: Feature B
EN 61000-4-6: Feature A
EN 61000-4-8: Feature A
EN 61000-4-11: Feature B
EN 61000-4-2: Feature A
EN 61000-4-3: Feature B
EN 61000-4-4: Feature A
EN 61000-4-5: Feature A
EN 61000-4-6: Feature A
EN 61000-4-8: Feature A
EN 61000-4-11: Feature A
EN 61000-4-2: Feature A
EN 61000-4-3: Feature B
EN 61000-4-4: Feature A
EN 61000-4-5: Feature A
EN 61000-4-6: Feature A
EN 61000-4-8: Feature A
EN 61000-4-11: Feature A
EN 61000-4-2: Feature A
EN 61000-4-3: Feature B
EN 61000-4-4: Feature A
EN 61000-4-5: Feature A
EN 61000-4-6: Feature A
EN 61000-4-8: Feature A
EN 61000-4-11: Feature A
Applied standards EN 61326
DIN EN 61010-1
IEC 61010 -1
VDE 0411-1
EN 61326
DIN EN 61010-1
IEC 61010 -1
VDE 0411-1
EN 61326
DIN EN 61010-1
VDE 0411-1
EN 61326
IEC 61010 -1
VDE 0411-1
DIN EN 61326
EN 61326
DIN EN 61010-1
VDE 0411-1
Protection IP 00 for device and interface connections
IP 20 for housing
IP 00 for device and interface connections
IP 20 for housing
IP 00 for device and interface connections
IP 20 for housing
IP 00 for device and interface connections
IP 20 for housing
IP 00 for device and interface connections
IP 20 for housing
Dimensions (W x H x D) 19'' x 4 standard height units
447 x 191 (177) x 541 (501) mm
19'' x 4 standard height units
447 x 191 (177) x 541 (501) mm
19'' x 2 standard height units
447 x 102 (88) x 541 (501) mm
19'' x 2 standard height units
447 x 102 (88) x 541 (501) mm
19'' x 2 standard height units
447 x 102 (88) x 541 (501) mm
Weight 16 20 10 10 10
Chapter06 Minimal output data Minimal output data Minimal output data Minimal output data Minimal output data
Voltage setting range 0V - 60V 0V - 60V 0V - 60V 0V - 60V 0V - 60V
Current setting range 0A - 120A 0A - 180A 0A - 40A 0A - 60A 0A - 30A
Power 3000W 4500W 800W 1500W 500W
Chapter07 Output characteristics Output characteristics Output characteristics Output characteristics Output characteristics
Setting resolution voltage 1 mV 1 mV 1 mV 1 mV 1 mV
Setting resolution current 2 mA 3.125 mA 1 mA 1 mA 1 mA
Setting accuracy (at 23 +/- 5 � C) voltage Sensing mode, 0.07% + 48 mV
No sensing mode, 0.07% + 60 mV
Sensing mode, 0.07% + 48 mV
No sensing mode, 0.1% + 60 mV
Sensing mode, 0.05% + 30 mV
No sensing mode, 0.05% + 48 mV
Sensing mode, 0.05% + 30 mV
No sensing mode, 0.05% + 48 mV
Sensing mode, 0.05% + 30 mV
No sensing mode, 0.05% + 48 mV
Setting accuracy (at 23 +/- 5 � C) current 0.1% + 135 mA 0.15% + 180 mA
Temperature coefficient of setting value ? K voltage 100 100 100 100 100
Temperature coefficient of setting value ? K current 100 100 100 100 100
Adjustment accuracy via analog interface (at 23 +/- 5 � C) voltage 0.6% + 150 mV 0.6% + 150 mV 0.6% + 120 mV 0.6% + 120 mV 0.6% + 120 mV
Adjustment accuracy via analog interface (at 23 +/- 5 � C) current 1.2% + 180 mA 1.2% + 240 mA 0.6% + 120 mA 1.2% + 120 mA 0.6% + 120 mA
Static control deviation at 100% load change voltage Sensing mode, 60 mV (<500 µV/A)
No sensing mode, 96 mV (< 800 µV/A)
Sensing mode, 90 mV (<500 µV/A)
No sensing mode, 144 mV ( < 800 µV/A)
Sensing mode, 30 mV (<500 µV/A)
No sensing mode, 48 mV (< 800 µV/A)
Sensing mode, 30 mV (<500 µV/A)
No sensing mode, 48 mV (< 800 µV/A)
Sensing mode, 30 mV (<500 µV/A)
No sensing mode, 48 mV (< 800 µV/A)
Static control deviation at 100% load change current 60 mA (<1000 µA/V) 90mA (<1500µA/V) 30mA (<500µA/V) 30mA (<500µA/V) 90mA (<1500µA/V)
Static control deviation at 10% line voltage change voltage 7mV 10mV 5mV 5mV 5mV
Static control deviation at 10% line voltage change current 30mA 60mA 5mA 5mA 5mA
Residual ripple voltage Ripple, 10 Hz ... 20 Hz, 60 mVss
Ripple, 10 Hz ... 1 MHz, 75 mVss
Ripple + noise, 10 Hz ... 10 MHz, 90 mVss / 10 mV TRMS
Ripple, 10 Hz ... 20 Hz, 80 mVss
Ripple, 10 Hz ... 1 MHz, 100 mVss
Ripple + noise, 10 Hz ... 10 MHz, 120 mVss / 15 mV TRMS
Ripple, 10 Hz ... 20 Hz, 40 mVss
Ripple, 10 Hz ... 1 MHz, 50 mVss
Ripple + noise, 10 Hz ... 10 MHz, 60 mVss / 6 mV TRMS
Ripple, 10 Hz ... 20 Hz, 40 mVss
Ripple, 10 Hz ... 1 MHz, 50 mVss
Ripple + noise, 10 Hz ... 10 MHz, 60 mVss / 6 mV TRMS
Ripple, 10 Hz ... 20 Hz, 40 mVss
Ripple, 10 Hz ... 1 MHz, 50 mVss
Ripple + noise, 10 Hz ... 10 MHz, 60 mVss / 6 mV TRMS
Residual ripple current Ripple + noise, 10 Hz ... 10 MHz, 70 mA TRMS Ripple + noise, 10 Hz ... 10 MHz, 100 mA TRMS Ripple + noise, 10 Hz ... 10 MHz, 50 mA TRMS Ripple + noise, 10 Hz ... 10 MHz, 50 mA TRMS Ripple + noise, 10 Hz ... 10 MHz, 50 mA TRMS
Settling time of output voltage tolerance 120mV 120mV 120mV 120mV 120mV
Settling time of output voltage ?I10% 400 µS 500 µs 100 µS 100 µS 100 µS
Settling time of output voltage ?I 80%&approx.800A/ms 1200µS 1600 µS 500 µs 400 µS 600 µS
Settling time of output voltage ?I -80%&approx.1200A/ 1900 µS 250µS 650 µS 500 µs 950 µS
Overshooting/undershooting of output voltage ?I 10% 200mV 250mV 150mV 150mV 150mV
Overshooting/undershooting of output voltage ?I 80% 1200mV 1300mV 550mV 700mV 500mV
Response times of the output voltage tolerance 120mV 120mV 120mV 120mV 120mV
Response times of the output voltage at step Uset 0V-Unom Idle / nominal load, 4 ms / 15 ms Idle / nominal load, 7 ms / 19 ms Idle / nominal load, 2 ms / 2 ms Idle / nominal load, 2 ms / 2 ms Idle / nominal load, 2 ms / 2 ms
Response times of the output voltage at step Uset 0V-Unom-1V Idle / nominal load, 70 ms / 11 ms Idle / nominal load, 70 ms / 11 ms Idle / nominal load, 70 ms / 15 ms Idle / nominal load, 70 ms / 11 ms Idle / nominal load, 70 ms / 20 ms
Response times of the output voltage at step Uset 0V - 16.7V/20V/25V Idle / nominal load, 1.2 ms / 6 ms Idle / nominal load, 2.4ms / 11 ms Idle / nominal load, 1.4 ms / 1.4 ms Idle / nominal load, 1.4 ms / 1.4 ms Idle / nominal load, 1.4 ms / 1.4 ms
Response times of the output voltage at step Uset 0V - 16.7V/20V/25V - 1V Idle / nominal load, 16 ms / 6 ms Idle / nominal load, 16 ms / 6 ms Idle / nominal load, 16 ms / 3 ms Idle / nominal load, 16 ms / 3 ms Idle / nominal load, 16 ms / 5 ms
Output capacitor sink nominal value 4040µF 6060µF 2020µF 2020µF 2020µF
Output capacitor sink performance 80W - 130W 120W - 195W 40W - 65W 40W - 65W 40W - 65W
Chapter08 Measuring function Measuring function Measuring function Measuring function Measuring function
Voltage measurement measuring ranges -16.384V - 98.3V -16.384V - 98.3V -16.384V - 98.3V -16.384V - 98.3V -16.384V - 98.3V
Current measurement range -65.532A - 196.6A -98.298A - 294.9A -32.766A - 98.3A -32.766A - 98.3A -32.766A - 98.3A
Power measuring range U x I U x I U x I U x I U x I
Voltage measurement resolution 2 mV 2 mV 2 mV 2 mV 2 mV
Current measurement resolution 4 mA 6 mA 2 mA 2 mA 2 mA
Power measurement resolution 100 mW 100 mW 100 mW 100 mW 100 mW
Measuring accuracy (at 23 +/- 5 � C) voltage 0.07% + 48 mV 0.1% + 48 mV 0.05% + 30 mV 0.05% + 30 mV 0.05% + 30 mV
Measuring accuracy (at 23 +/- 5 � C) current 0.6% + 120 mA 0.8% + 180 mA 0.4% 90 mA 0.4% 90 mA 0.4% 90 mA
Measuring accuracy (at 23 +/- 5 � C) power 0.7% + 2 W 1% + 3 W 0.5% + 1 W 0.5% + 1 W 0.5% + 1 W
Temperature coefficient of the measured value ? K voltage 50 ppm + 0.6 mV 50 ppm + 0.8 mV 50 ppm + 0.4 mV 50 ppm + 0.4 mV 50 ppm + 0.4 mV
Temperature coefficient of the measured value ? K current 100 ppm + 2 mA 100 ppm + 3 mA 100 ppm + 1 mA 100 ppm + 1 mA 100 ppm + 1 mA
Measuring accuracy at analogue interface (at 23 +/- 5 � C) voltage 0.6% + 180 mV 0.8% + 180 mV 0.4% + 120 mV 0.4% + 120 mV 0.4% + 120 mV
Measuring accuracy at analogue interface (at 23 +/- 5 � C) current 1.2% + 240 mA 1.2% + 300 mA 0.5% + 180 mA 1.2% + 180 mA 0.5% + 180 mA
Chapter09 Protection and additional functions Protection and additional functions Protection and additional functions Protection and additional functions Protection and additional functions
Output surge voltage protection setting range 3V - 80V 3V - 80V 3V - 80V 3V - 80V 3V - 80V
Output surge voltage protection setting resolution 20mV 20mV 20mV 20mV 20mV
Output surge voltage protection setting accuracy +/- 150 mV - 20 mΩ x Ia +/- 150 mV - 20 mΩ x Ia +/- 150 mV - 20 mΩ x Ia +/- 150 mV - 10 mΩ x Ia +/- 150 mV - 10 mΩ x Ia
Output surge voltage protection response time 200 µs 200 µs 200 µs 200 µs 200 µs
Output overcurrent protection setting range 6A - 160A 50mA 9A - 240A 100mA 2A - 53A 20mA 3A - 80A 20mA 1.5A - 40A 20mA
Output overcurrent protection setting resolution - (1% + 500 mA) - 40 mA/V x Ua - (1% + 700 mA) - 60 mA/V x Ua - (1% + 350 mA) - 20 mA/V x Ua - (1% + 350 mA) - 20 mA/V x Ua - (1% + 350 mA) - 20 mA/V x Ua
Output overcurrent protection response time 200 µs 200 µs 200 µs 200 µs 200 µs
Withstand capacity of protection against polarity reversal 120A 180A 40A 60A 30A
Reverse voltage withstand capacity 70V 70V 70V 70V 70V
Auto-sensing mode compensatable voltage drop per load � 1V 1V 1V 1V 1V
Chapter10 General General General General General
Supply at rated line voltage 230V line voltage 3 x 230 V / 400 V ~ +10/-15% 3 x 230 V / 400 V ~ +10/-15% 230 V ~ +10/-15% 230 V ~ +10/-15% 230 V ~ +10/-15%
Supply at rated line voltage 230V frequency 47Hz - 63Hz 47Hz - 63Hz 47Hz - 63Hz 47Hz - 63Hz 47Hz - 63Hz
Supply at rated line voltage 230V at nominal load 50% 3810 VA, 3710 W 5660 VA, 5500 W 1050 VA, 1000 W 1925 VA, 1865 W 700 VA, 650 W
Supply at rated line voltage 230V on no-load 100 VA, 45 W 110 VA, 55 W 96 VA, 37 W 96 VA, 37 W 96 VA, 37 W
Supply at rated line voltage 115V line voltage 3 x 115/200 V ~ +10/-15% 3 x 115/200 V ~ +10/-15% 3 x 115/200 V ~ +10/-15% 115 V ~ +10/-15% 115 V ~ +10/-15%
Supply at rated line voltage 115V frequency 47Hz - 63Hz 47Hz - 63Hz 47Hz - 63Hz 47Hz - 63Hz 47Hz - 63Hz
Supply at rated line voltage 115V at rated load 50% 2215 VA, 2180 W 3305 VA, 3255 W 1175 VA, 1150 W 1125 VA, 1100 W 800 VA, 750 W
Supply at rated line voltage 115V on no-load 73 VA, 48 W 92 VA, 60 W 55 VA, 36 W 55 VA, 36 W 55 VA, 36 W
Max. power loss at nominal load 500/800/1500W (230V) 710W 1100W 200W 365W 150W
Max. power loss at nominal load 500/800/750W (115V) 680W 1030W 350W 350W 250W
Efficiency at rated load 500/800/1500W (230V) 81% 82% 80% 80% 77%
Efficiency at rated load 500/800/750W (115V) 69% 69% 70% 68% 66%
Switching frequency PFC/DC 47 kHz / 230 kHz 47 kHz / 230 kHz 47 kHz / 230 kHz 47 kHz / 230 kHz 47 kHz / 230 kHz
MTBF time at 40�C > 40,000 h > 30,000 h > 50,000 h > 50,000 h > 50,000 h